No stinkin’ codes

by DebbieWTR
April 26, 2012

” We don’t need no stinkin’ codes.  Outlet boxes mounted to a baseboard are probably not up to code.” Safe? Yes or No???

Loading...
Power Can Opener
Gettin a Step Up – White Trash Repairs
Redneck hot tub – White Trash Repairs
Hungry?
White Trash Chandelier
5552
6176
Ladder Hauler
Redneck Lounge Chairs
U CAN’T C ME!
Loading...
  • # Baseboard, Outlet Boxes
PrevPreviousRedneck Cooler Stereo (Video)
NextEpic Wire FailureNext

6 thoughts on “No stinkin’ codes”

  1. kbrackie
    April 27, 2012 at 7:00 am

    It may be tacky but, doesn’t look like it’s in the U.S. Only potential problem I see is the exposed wire. I would have mounted it on the wall and run the wire in conduit.

  2. Ugnaught
    April 27, 2012 at 3:06 pm

    There’s no exposed wire here. If those metal boxes are connected to the ground wire in those Romexes, this is pretty safe, even though it’s tacky, and probably violating the electrical code.

  3. formersparky
    April 27, 2012 at 8:35 pm

    Yes, this is in the US. No, unshielded romex is for sure against code. I highly doubt that those are dust-proof receptacles, which they should be (by code) since they are facing straight up. Those appear to be standard 120v 15/20A single receptacles. Keep hitting the romex with a vacuum cleaner and see how long the romex insulation lasts. The romex should be in some form of raceway by code.

  4. sparkin'
    April 28, 2012 at 5:21 am

    Blade configuration looks wrong for U S.

  5. Silver Turtle
    April 28, 2012 at 2:41 pm

    Fire waiting to happen — no dust covers; improper mounting [need to be recessed INTO the floor]. If they were mounted so that the outlets were facing out and they rerouted the wire through the rear of the box — they MIGHT pass, but I doubt it.

  6. Stuff
    July 8, 2012 at 3:07 pm

    20 AMP service plug for high power usage machines like AC’s cleaners, etc. not too common of a plug anymore. would be legal if it was shielded cable